Agilent 16533A, 16534A Digitizing Oscilloscope (help volume) - download pdf or read online

Read Online or Download Agilent 16533A, 16534A Digitizing Oscilloscope (help volume) PDF

Similar nonfiction_6 books

Get Non-Stop (SF Masterworks 33) PDF

Interest used to be discouraged within the Greene tribe. Its contributors lived out their lives in cramped Quarters, hacking away on the encroaching ponics. As to the place they have been - that used to be forgotten. Roy whinge makes a decision to determine. With the renegade priest Marapper, he strikes into unmapped territory, the place they make a chain of discoveries which flip their universe upside-down.

Additional resources for Agilent 16533A, 16534A Digitizing Oscilloscope (help volume)

Example text

Use accumulate to measure jitter or eye diagrams, see a waveform's envelope, look for timing violations, and find infrequent events. Average When Averaging is enabled, the # Avgs control tells the oscilloscope the number of waveforms you want to use in calculating the average value for each sample point. The Agilent Technologies 16533A or 16534A oscilloscopes can average from 2 to 512 waveform acquisitions but the larger the number of acquisitions, the more time it will take to accumulate all the waveforms you have requested.

3. Select the Grid Type option button to change the grid to axes-only scales, frame-only scale, or a background grid. The intensity field controls the brightness. You cannot change the grid color. 51 Chapter 1: Agilent Technologies 16533/34A Digitizing Oscilloscope Vertical and Horizontal Scaling Vertical and Horizontal Scaling The vertical scale is volts per division (V/div). Changing the vertical scale affects the height of the waveform. Extreme changes to the vertical scale can affect your offset values.

The kit contains enough parts for two probes. The Agilent Technologies 116x probe tip plugs into the single-lead end of the dual-lead adapter. The MicroGrabber connects to the red lead. You can also use a MicroGrabber on the black lead, which you should connect to your circuit's ground. 025 inch) in diameter. The kit is intended for use with voltages no greater than ±40 V (dc and ac peak). 30 Chapter 1: Agilent Technologies 16533/34A Digitizing Oscilloscope Acquiring a Waveform Acquiring a Waveform The two ways to acquire a waveform with the oscilloscope are Autoscale and Run.

Download PDF sample

Agilent 16533A, 16534A Digitizing Oscilloscope (help volume)


by Mark
4.2

Rated 4.04 of 5 – based on 13 votes